Safe Line, SL6, main unit (PSTN)
Technical Information:<?xml:namespace prefix = "o" ns = "urn:schemas-microsoft-com:office:office" />
Power supply: 230 VAC
Power consumption: 25 W
Power supply (LED): 30 W
Output voltage: 12 VDC
Battery: 12 VDC, 1.2 Ah
IP rating: IP20
Inputs: 1030 VDC, 5 mA
Antenna connector: SMA
Power usage: 230 VAC, 610 W
Dimensions (H × W × D): 241 × 160 × 47 mm
Weight: 1700 g
Description:
This PSTN main unit for the SL6 system can be installed in the machine room, the shaft, or on the lift car, and connected to an analogue landline (PSTN). Combine the SL6 main unit with up to 6 speech units per system to create a complete emergency communication solution.
An internal 4-wire bus system ensures very simple and efficient wiring between devices. The SL6 complies with EN81-28 and EN81-70, and also functions as a fully integrated fire communication system exceeding the legal requirements. In the event of a fire alarm, the speech units act as an intercom and can be activated via a dedicated key switch accessible from the building entrance.
Even easier: no PC is required for configuration. With integrated Bluetooth, the SL6 can be fully set up wirelessly using the SafeLine LYNX app on any smartphone. The app is available free of charge on the App Store and Google Play.